How to Remove Terminals from Housings.

Posted on 21. Mar, 2010 by in Tech Articles

In this article we will cover how to remove a Weather Pack terminal from a housing. There is a special tool included with both the 460 and 755 piece Weather Pack kits that will allow you to do this easily.


Above is a complete Weather Pack connector and the terminal removal tool.


Here we see inside these housings that the terminals are reversed from that of a standard Weather Pack assembly. The male terminals should go into the shroud housing and the female terminals should go into the tower housing. Let’s see if we can correct this.


Start by opening the rear section of each housing.


Insert the terminal removal tool down over each terminal all the way until it won’t go any farther.

With the terminal removal tool held firmly all the way into the housing, pull the terminal and wire combo out the opposite side.


Continue the same process for all the terminals that need to be removed.


After removing the terminals, I installed them all into the correct housing.


Let’s have a closer look at how this tool works.


Here we see the terminal removal tool paired up with a female Weather Pack terminal. Notice the metal tangs on the terminal. These are what lock the terminals into the housings.


They look very close in size but the tool is just slightly larger than the terminal, allowing it to slip over top.


Notice in this image above that the tool has been slid down over the metal tangs. By pressing the tangs in, the terminal is then free to be removed.

Tags: , , , ,